Most homes here already run on electric heat
Electricity heats 56.8% of occupied homes in Garfield County, more than any other fuel. A heat pump fits that setup without any new fuel line or tank to deal with.

Takes about a minute. No obligation.
Electricity heats 56.8% of occupied homes in Garfield County, more than any other fuel. A heat pump fits that setup without any new fuel line or tank to deal with.
An electric furnace or electric baseboard can run on a different circuit than a heat pump needs. Whoever installs it should check the panel and the existing circuit before quoting the job.

NOAA nClimDiv, 1991–2020 normals
Half the homes in Garfield County were built in 1957 or earlier.
An old duct system or an old electrical run can limit which heat pump fits, so that's worth checking before the installer quotes a size.




Winter here averages 27°F overnight through December, January and February, which is mild as far as heat pumps go. The outdoor unit still has to sit through wind and winter storms, which hit this county often enough to plan around, but hail almost never shows up here. None of that adds up to hard use. A heat pump sized right for this house doesn't need to be the highest-efficiency model on the lot to hold up for years.
Garfield County sits in climate zone 5B, where heating carries the bigger load. Federal rules set the floor for what can go in. Split-system heat pumps made from 2023 on must hit at least 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. A federal tax credit is available toward a system that qualifies. Get a quote to see what fits your home.
Find a contractorSEER2 and HSPF2 measure how much heat a unit moves for the power it draws. A higher number costs less to run over the life of the equipment. It says nothing about comfort and nothing about how long the unit lasts. A well-built unit at the minimum rating can outlast a poorly installed one at the top of the range. The rating also assumes the system is sized and charged correctly. A heat pump that's oversized, undersized, or low on refrigerant won't hit its rated efficiency no matter what the label says. The number is a starting point for comparing equipment, not a promise about the power bill.
A heat pump has to match the heat loss of the house it's going into, and getting that right takes a load calculation, not a guess based on the old system's size. Go too small and it struggles on the coldest mornings. Go too big and it short cycles, wearing itself out faster. Either mistake costs more than the calculation would have.
If the existing ducts are sealed, sized right, and in good shape, the installer connects the new system and moves on. If they're leaky or undersized for a heat pump's airflow, that work has to happen first or the system never performs the way it's rated to. It's worth asking the installer to look at the ducts before assuming the quote only covers the equipment.
A load calculation looks at the walls, the windows, the ceiling height, and how much of the house faces into the weather, then adds it up room by room. That's what sizing a heat pump actually means, not matching the tonnage of whatever is being replaced. The old system might have been wrong from the day it went in. Too small and the heat pump runs flat out on the coldest nights and still falls behind. Too big and it blasts the house to temperature fast, shuts off, then starts again a few minutes later, which wears on the compressor more than running longer at a steady pace ever would. Right-sized, it runs long and low most of the time, which is exactly how a heat pump is supposed to work.
The old equipment comes out first. Lines get disconnected, and the pad or mounting bracket outside gets checked before the new unit sits on it. Refrigerant lines get run or reused, then pressure tested for leaks before anything gets charged. Electrical work happens as its own step. The disconnect box, the circuit, and the thermostat wiring all have to match what the new system needs, and that isn't always what the old one used. Once everything is connected, the system gets charged with refrigerant to the manufacturer's spec. The installer checks airflow at the vents and the temperature split across the coil before calling it done. The thermostat gets set up last, after the system is confirmed to respond to it the way it should.