Most homes here run on electric heat
Electricity heats 61.9% of homes in Clark County, more than any other fuel. Gas is a distant second at 33.3%.
Takes about a minute. No obligation.
Electricity heats 61.9% of homes in Clark County, more than any other fuel. Gas is a distant second at 33.3%.
If your home heats with electricity now, a heat pump works with the wiring and setup you already have. The install is about sizing the right system and running the ductwork it needs, not switching fuels.

NOAA nClimDiv, 1991–2020 normals
Electricity in Washington runs about 11.90 cents per kilowatthour, cheaper than most of the country.
A heat pump still beats electric resistance heat here, but the payback on paying more for a high-efficiency model stretches out. Fit and reliability matter more than squeezing out another SEER2 point.




Clark County sits in climate zone 4C, which asks real work of a system in both directions. A heat pump installed here has to clear federal minimums for this kind of equipment, 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. That floor rules out older or stripped-down units once existing stock runs out. Most manufacturers build well past it, so meeting the number isn't the hard part. Sizing the system to your home, and to this climate, is.
At 35°F average overnight lows, this system won't be straining through winter. That's a case for picking equipment that's well built and sized right, not for paying up for the highest efficiency number on the shelf.
Find a contractorA heat pump installation isn't priced off one number on a spec sheet. The equipment itself is only part of it. Ductwork drives a lot of the cost, since a system sized correctly for the home still needs ducts that can carry the air it moves, and modifying or adding duct runs takes real labor. The electrical side matters too. A heat pump often draws differently than whatever heated the home before, so a new circuit or a panel upgrade can be part of the job rather than an extra. Where the outdoor unit sits and how far the line set has to run between indoor and outdoor parts changes the labor as well. Removing old equipment, especially a furnace with a gas line that needs capping, is its own step with its own time attached. None of this is padding. It's the work that determines whether the system runs the way it's rated to.
SEER2 and HSPF2 come from a fixed test, run at set temperatures with set airflow. Your home will not match that test. The number tells you how one unit compares to another unit under the same conditions, not what your power bill will look like.
A high-efficiency heat pump still needs the right size for the space and ductwork that can actually move the air it produces. Oversize it, undersize the ducts, or skip a careful charge, and it runs worse than a plainer unit installed correctly. The rating describes the equipment, not the install.
Whoever installs the new heat pump should be able to take the old equipment with them, so ask about that up front if you'd rather not deal with it yourself. If the old system is a central air conditioner, the refrigerant inside has to be recovered properly before the unit comes apart, not vented. That's a legal requirement, not a courtesy, so a licensed contractor will already have the equipment for it. If you're replacing a furnace alongside the heat pump, check whether it's gas. Gas equipment needs the line capped off safely, which is its own step separate from pulling the unit out. None of this is something to handle on your own timeline. It gets folded into the same visit as the install.
Install day starts with the outdoor unit and the indoor coil, and most of the time goes into the parts you don't see. The refrigerant lines get run or reused, pressure tested, then pulled into a vacuum to clear out moisture and air before any refrigerant goes in. That vacuum step isn't optional and it isn't quick. The electrical side needs its own circuit sized to the new unit, which isn't always what the old equipment used, so that gets checked rather than assumed. Once everything is connected, the system gets charged to the manufacturer's spec and run through both modes, cooling and then heat, to check airflow and temperature split before anyone calls it done.