Cold, not punishing
Winter nights in Othello average 25°F. That's cold enough for a heat pump to work for its keep, but it's not the kind of extreme that wears a system down early.
Takes about a minute. No obligation.
Winter nights in Othello average 25°F. That's cold enough for a heat pump to work for its keep, but it's not the kind of extreme that wears a system down early.
If your heat pump is acting up, it's more likely a specific part failed than that the system is worn out from fighting the climate here. That's worth knowing before you decide whether to fix it.

NOAA nClimDiv, 1991–2020 normals
Heat starts running in September here.
The first cold snap in September is when a weak part finally gives out.




A failed capacitor or contactor doesn't mean much on its own. Those parts wear out and get replaced, and a heat pump that's otherwise sound is worth fixing for that. It's a different story when the compressor is the problem, or when the system keeps losing refrigerant and needs another charge. Those point to a system wearing out rather than a part giving out. The other thing worth paying attention to is whether the same unit keeps coming back for repairs. One breakdown is a part failing. A pattern of them is the system telling you it's done.
If your heat pump came with the house, ask the contractor how old it actually is before paying for a repair. That's worth doing here more than most places, since half the homes in Adams County date to 1977 or earlier. A compressor problem or a system that keeps needing refrigerant is worth weighing against that age. A failed capacitor or contactor is worth fixing regardless.
Find a contractor
A heat pump runs in both directions, so it never really gets a season off. That's more cycles on the reversing valve, more starts on the compressor, more hours on the outdoor fan motor than a straight air conditioner ever sees. Most of what goes wrong announces itself before it's an emergency. The system runs but blows air that's not warm enough, or not cold enough. It short cycles, kicking on and off every few minutes instead of running a full stretch. Ice builds up on the outdoor coil and doesn't clear during defrost. It makes a noise it didn't used to make, a buzz from the contactor or a clank from somewhere in the outdoor unit. Any of those is worth a call before the part that's struggling takes something else down with it.
A compressor that's struggling draws harder every time it starts. Run it long enough in that state and the windings overheat or the start components fail too. What might have been one repair turns into a compressor replacement.
A heat pump low on charge still runs, just harder. The compressor has to work longer to move the same heat, which pushes up wear on top of whatever caused the leak in the first place. Topping it off without finding the leak just buys time, not a fix.
Before you call anyone, there are a few things worth checking yourself. Look at the outdoor unit and clear away anything blocking it, leaves, a stray branch, snow piled against the side. Check the thermostat is set to heat and the temperature is actually above room temperature, it sounds obvious until that's the whole problem. Go look at the air filter. A filter clogged with dust chokes airflow and can make a heat pump seem like it's failing when it's just starved for air. Check the breaker panel too, a tripped breaker will shut the whole system down and look like a bigger problem than it is. If the outdoor unit is caked in ice and it's not in a defrost cycle, that's worth noting but not something to chip at yourself. None of this fixes a bad capacitor or a refrigerant leak, but it rules out the simple stuff first.
A diagnostic visit starts outside at the unit, checking voltage and amperage against what the system is rated for. Next comes gauges on the refrigerant lines, because too little charge and too much both cause their own kind of trouble. Electrical parts get tested under load, not just looked at, since a capacitor or contactor can sit there looking fine and still fail the moment it has to work. Airflow gets checked too, across the coil and through the ducts, since weak airflow can look like a failing part when it isn't one. By the end there should be a straight answer about which part failed and why. A compressor problem or a refrigerant leak takes longer to run down, because those hide behind symptoms that look simpler than they are.