Can a heat pump keep up on a Grant County winter night
Your winters here are long and your nights get cold. Heat runs eight months a year, October through May, and the overnight low averages 25°F across December, January and February. About 125 nights a year dip to freezing or below. That is half the nights in the whole heating season.
A standard heat pump starts losing ground before it gets anywhere near 25°F. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to cover the gap. Your average winter low sits under both marks, and every one of those 125 freezing nights does too. That is not a cold snap here and there. That is most of the season.
This is less of a problem than it sounds. Only about 2 nights a year reach 0°F, where a heat pump struggles most. And cold-climate heat pumps are built for exactly this. To earn that label, a heat pump has to keep making heat efficiently at 5°F, and hold onto most of its capacity doing it. In field testing, homes with these units pulled most of their heat from the heat pump itself through the whole range from 0°F to 35°F. Backup heat filled in a small share, and running on backup alone was rare except on the very coldest nights. A furnace never has this problem. It burns gas and makes full heat at any temperature, 25°F or 25 below.