Illuminated timber-and-stone houses line a residential street at dusk, with evergreen trees in the foreground and a silhouetted mountain range behind them.

Heat Pump Repair in Walla Walla, WA

Tell us about the job

Takes about a minute. No obligation.

RepairHeat PumpWalla Walla County, WA
Step 1 of 2

What ZIP code is the job in?

The first cold week in October finds it

A heat pump with a weak part can coast for months without being asked to do much. Once heat season starts in October, it has to run every day, and whatever was already marginal usually shows up in that first stretch.

July asks the same question in reverse

Cooling only runs two months here, July and August, so a struggling compressor or low charge can go unnoticed the rest of the year. The first hot days put real load on it, and that is when the problem gets found.

8 months
October through May, your system heats
2 months
July through August, it cools
29°F
the average winter night it heats against
86°F
the average summer afternoon it cools against
Isometric grayscale illustration of a cutaway two-story house showing interior ductwork, an indoor air handler unit, and an outdoor condenser unit on a pad beside the building.
Your system heats October through May and cools July through August.

NOAA nClimDiv, 1991–2020 normals

Winter nights average 29°F here, and your heat pump isn't fighting extreme cold or heavy loads most of the year.

A heat pump that hasn't been run hard is usually a heat pump worth fixing, not replacing.

Half the homes here are old enough that their heat pump is on its second or third one

Half the homes here were built by 1973
37 damaging wind events from 2015 to 2024
67 winter storms from 2015 to 2024

Ask what's left in it before you pay to fix it

If your heat pump came with the house, find out its age before you approve a repair. A unit on its second or third replacement may not be worth another part. A contractor can tell you where it stands and whether this repair makes sense.

Find a contractor
A man in a dark jacket, cap and tan work pants carries a canvas tool bag up stone steps toward a navy front door, with a potted shrub beside the entry.
A gray heat pump outdoor unit mounted on a concrete pad next to the stone-accented exterior wall of a house.

What to check before you pick up the phone

Before anyone comes out, check the thermostat batteries and the setting itself. A thermostat set to the wrong mode can look exactly like a dead heat pump. Go outside and look at the outdoor unit. If it's caked in ice, that can be normal during a defrost cycle, but a unit that's frozen solid and never clears on its own points to a real problem. Check that the outdoor unit isn't blocked by leaves, snow, or anything piled against it, since airflow in and out of that cabinet matters as much as airflow inside the house. Go to the air handler or indoor unit and look at the filter. A filter clogged with dust chokes the system and can trip it into a protective shutdown. Walk the vents in the house and make sure none of them are closed or blocked by furniture. Check the breaker panel for a tripped breaker before assuming the worst, since a heat pump that won't start at all sometimes just needs a reset. If the system runs but blows air that feels wrong for the mode you're in, that's worth mentioning to whoever comes out, since it points toward the reversing valve rather than something simpler.

A refrigerant leak doesn't hold still

A heat pump low on charge will still heat the house, just not as well, and it's easy to let that slide. But a system running low keeps losing what it has, and the compressor depends on refrigerant flowing back to it correctly to stay cool and lubricated. Run it long enough in that state and a leak that started as a simple recharge turns into a compressor replacement.

A noise that comes and goes is still worth a call now

A rattle or a squeal that only shows up sometimes is easy to explain away, especially if the heat pump keeps working. But a loose part that vibrates against a panel will wear a hole in it eventually, and a bearing that squeals under load is already on its way out. Catching it while it's intermittent is a smaller job than catching it after it fails.

Most heat pump failures trace back to one of a few parts. The reversing valve is the part unique to a heat pump, the thing that lets it switch between heating and cooling, and when its coil burns out or the valve itself sticks, the system gets stuck in one mode or stops responding to the thermostat correctly. The defrost board and its sensor are another common point of failure, since that's what tells the unit when to clear frost off the outdoor coil and when to go back to heating. Capacitors wear out on the compressor and the fan motors, usually showing up as a unit that hums but won't start, or a fan that spins slow. Refrigerant doesn't get used up, so if a system is low, it's leaking somewhere, and that leak won't fix itself. Outdoor fan motors fail too, and a compressor that keeps running without one overheats fast.

A diagnostic starts outside at the unit itself, not with a guess. The tech checks refrigerant pressures on both the high and low side, since that number tells them whether the charge is right, whether there's a restriction, or whether the compressor is struggling to do its job. They'll check the temperature split between the air going into the indoor coil and the air coming out, which tells them if the system is actually moving heat the way it should. Electrical readings on the compressor and fan motors come next, since a motor can draw the wrong amperage long before it fails outright. They'll run the system through a defrost cycle on purpose if the complaint points that way, watching whether the reversing valve actually switches and whether the board brings the unit back to heating when it should. None of this is guesswork. Each reading rules something in or out until one part is left that explains what the homeowner is seeing.