Cold enough to need backup, not cold enough to need gas
Your furnace runs about ten months a year here, September through June, and the overnight low averages 34°F across December, January and February. That number matters more than it looks like it should. A standard heat pump starts losing ground to its own rating below 40°F, and below about 35°F it often leans on backup heat to keep up. Your average winter night here sits below both marks. That doesn't mean a heat pump can't heat your house. It means that on a typical winter night, it's already working harder than its rating suggests, not just on the rare cold snap.
The nights that actually get below freezing here, about 40 a year, are under a quarter of the nights the heat runs at all. And almost none of them go further than that. Fewer than one night a year drops to 0°F or below. That's the number that usually worries people considering a heat pump in a cold state, and it's not a number this county has. The cold-climate heat pumps built and tested for places that do see 0°F still carry most of the load themselves even at that temperature, running on backup alone only rarely. A county that almost never sees 0°F is an easier case than that, not a harder one.
So the honest read on comfort is this: a heat pump will keep your house warm here. The 40 nights at or below freezing are the nights it works hardest and may call on backup heat, not the nights it fails. A furnace sidesteps that question entirely, because it makes the same strong heat regardless of what it's like outside.