Can a heat pump keep up here
Winters here are mild but long. The heat runs ten months a year, September through June, and the overnight low averages 29°F through December, January and February. That number matters because a standard heat pump starts losing ground before it gets that cold. Below 40°F it puts out less than its rated capacity, and below about 35°F it often needs backup heat to make up the difference. At 29°F, this county's average winter night, a standard heat pump is already past both marks.
About 65 nights a year here drop to freezing or below, under a quarter of the nights the heat runs. Every one of those nights is cold enough to put a standard heat pump below both marks. None of them get close to 0°F, less than one night a year does, so the backup heat isn't fighting extreme cold, just a long stretch of ordinary chill.
If you buy a heat pump for this house, look for the ENERGY STAR Cold Climate listing. To earn it, a heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, checked by independent testing. That is a different machine from the federal-minimum model the running-cost number above is based on, and it is built for nights like the ones this county actually has. Field testing of cold-climate heat pumps in occupied homes backs this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F.