Winters here are long, not extreme
Heat runs about ten months a year in Chelan County, September through June. Whatever you install is working most of the year, so how it runs on an ordinary night matters more than how it handles a rare one.
The overnight low averages 22°F through December, January and February. About 130 nights a year dip to freezing or below, but only about 2 reach 0°F. So the real question isn't whether a system can survive an arctic snap. It's whether it keeps up night after night at or near that 22°F average, because that's what winter looks like here most of the time.
A standard heat pump starts losing ground well before it gets anywhere near 0°F. Below 40°F its heat output falls short of its rated capacity, and below about 35°F it often needs backup heat to make up the difference. The average winter low here is 22°F, under both marks, and every one of those 130 freezing nights falls under both too.
That doesn't rule out a heat pump. It means the one worth installing here is built for this, not the base model. The ENERGY STAR Cold Climate spec requires a heat pump to still make 1.75 units of heat for every unit of electricity at 5°F, and to hold onto at least 70 percent of its 47°F capacity at that temperature. A two-winter field test of prototype cold-climate heat pumps found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A furnace sidesteps the question entirely. It burns gas and makes full heat no matter what it's like outside.