Can a heat pump keep up here
Your winter nights average 24°F, and about 135 of them drop to freezing or below. That matters because a standard heat pump starts losing heat output below 40°F and often leans on backup heat below about 35°F. Here, every single freezing night falls under both marks. The question isn't whether it gets cold enough to matter. It does, for most of the heating season.
That doesn't mean a heat pump can't do the job. Cold climate models are built and tested for exactly this. To earn that rating, a heat pump has to keep making real heat, at least 1.75 units of heat per unit of electricity, at 5°F, and hold onto most of its capacity at that temperature. A field test of these units in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even near 0°F. Your county sees 0°F about once a year. So the cold itself isn't the obstacle, the equipment is. A heat pump built to the federal minimum will struggle on your coldest nights. One built and rated for cold climates is a different machine for the same house.
A furnace doesn't have this question at all. It burns gas, makes heat on demand, and the outdoor temperature doesn't change how it runs. On a 0°F night it works the same as it does at 32°F.